DCL Series Fiberglass Dispenser Sump
The PCI DCL Series Dispenser Sump provides secondary containment beneath fuel dispensers, enclosing piping connections, penetration fittings, and shear valves with access for installation, inspection, and service.
Built from 100% corrosion-resistant fiberglass with a heavy-gauge steel frame, the DCL features double conduitless entry. Electrical conduits can enter the dispenser at both ends without penetrating the sump walls, reducing unnecessary penetrations.
Double Conduitless Entry
Electrical entry at both ends of the dispenser provides flexibility for conduit placement while reducing the number of penetration fittings and potential entry points for outside moisture.
Room for Multiple Product Entries
Extended sump walls provide room for up to five product entries on applicable models, accommodating multiple product lines beneath the dispenser.
Heavy-Gauge Steel Frame
The steel frame provides strength and rigidity and is designed to lock into the concrete foundation for secure dispenser mounting.
Single-Piece Sump Body
The fiberglass body is constructed as a single piece, eliminating body seams and supporting dependable containment.
Duo-Molded Fiberglass Construction
PCI’s Duo-Molded Technology combines two layers of fiberglass with high glass content for strength and fuel resistance.
Brite-White Interior
PCI’s Brite-White interior reflects light for better visibility and helps identify leak points during inspection and service.
Universal Stabilizer Bars
Universal stabilizer bars provide three-axis adjustment to accommodate multiple product lines without displacing piping. The assembly supports proper load transfer during dispenser impact and is ordered separately.
Composite Rainlip
A 1-inch composite rainlip helps prevent surface runoff from entering the sump and resists rust and corrosion.
Nestable Design
Multiple sumps nest together to reduce shipping volume and warehouse space, helping lower freight costs and simplify inventory handling.
Factory Pre-Plumbed Options
Full and partial factory pre-plumbing are available to reduce field assembly and installation time. Each pre-plumbed sump is built to your specifications and hydrostatically and pressure tested before shipment.
Double Wall Options
Double wall models are available for installations requiring interstitial monitoring, with configurations supporting dry, vacuum, or fluid-filled monitoring. Required monitoring accessories are ordered separately.
Dispenser Compatibility
Available models include:
- DCL146360B: Bennett Pacific
- DCL174360: Gilbarco Encore
- DCL170360: Wayne Helix 48-inch
- DCL146360: Wayne Ovation
- DCL112360: Wayne Vista 48-inch
Corresponding double wall models and additional configurations are available.
Specifications and Installation Resources
Download the product brochure and installation instructions for model dimensions, dispenser compatibility, stabilizer kits, and installation requirements.

Standard Features

‘BRITE-WHITE’ INTERIOR
Our signature ‘Brite-White’ interior reflects light for better visibility and makes identifying leak points easier.

100% Fiberglass
100% high-quality, non-corrosive fiberglass provides long-term reliable containment from fuel exposure without voiding warranty, warping, cracking or becoming brittle.

Duo-Molded Technology
Our fiberglass sumps utilizes Duo-Molded Technology. Using premium raw materials with a high glass content, we create two layers of fiberglass, offering superior strength and fuel resistance.
UNIVERSAL STABILIZER BARS
Universal stabilizer bars with 3-axis adjustment accommodate multi-product dispensers without displacing product lines and ensure proper load transfer in case of an impact from any direction.

SINGLE PIECE CONSTRUCTION
Constructed as a single piece which eliminates any seams, providing less places for water penetration.

1″ COMPOSITE RAINLIP
1″ Composite Rainlip protrudes from the bottom of the dispenser to prevent surface water from entering the sump. This also offers better protection against rust and corrosion than metallic rainlips.
Optional Features

Double Wall Options Available
Available in double wall for a variety of monitoring options to satisfy local regulations and requirements. From dry fluid or fluid filled interstitial to vacuum interstice monitoring, PCI has all options to best fit your installation and compliance needs.

Pre-Plumbed Service Available
PCI’s Dispenser Sumps are available with completely customizable pre-plumb service built to customer’s specifications. Our pre-plumb dispenser sumps include all internal piping from the shear valve to penetration, eliminating the need for any additional field labor.
Dimensions
| Dispenser | Single Wall | Double Wall | Width | Length | Stabilizer Kit |
|---|---|---|---|---|---|
| Bennett Pacific | DCL146360B | DCLDW146360B | 14.75″ | 36″ | SVU-L |
| Gilbarco Encore | DCL174360 | DCLDW174360 | 17.5″ | 36″ | SVU-L |
| Wayne Helix 48″ | DCL170360 | DCLDW170360 | 17″ | 36″ | SVU-L |
| Wayne Ovation | DCL146360 | DCLDW146360 | 14.75″ | 36″ | SVU-L |
| Wayne Vista 48″ | DCL112360 | DCLDW112360 | 11.25″ | 36″ | SVU-S |
Additional Models Available
Additional Double Wall AcceSsories (ordered Separately)
| Part No. | Description |
|---|---|
| EQP-DW-VAC | Vacuum Kit (Required for all Double Wall Sumps) |
| EQP-IF-5GAL | Interstitial Fluid, 5 Gallons (Required for Double Wall Sumps with Fluid Filled Interstice) |
| EQP-IF-ADP-UC | Interstitial Fluid Adapter Kit ( 1 Per Sump, Required for Double Wall Dispenser & Grade Level Transition Sumps with Fluid Filled Interstice) |
To learn more about Double Wall Dispenser Sumps, Visit the Double Wall page »
Downloads
Regulatory
UL® Listed 2447
California Code of Regulation Title 23, Division 3, Chapter 16, Section 2631 (AB 2481/ California VPH)
State of Floria Department of Environmental Protection Approved / Registered Storage Tank System: EQ-203